[{"data":1,"prerenderedAt":27},["ShallowReactive",2],{"article-en-potato-flakes-reducing-sugar-testing-guide":3},{"source":4,"article":5,"navigation":20},"directus",{"id":6,"slug":7,"language":8,"title":9,"excerpt":10,"contentHtml":11,"publishedAt":12,"modifiedAt":12,"frontendPath":13,"featuredImage":14,"featuredImageAlt":9,"categories":15,"tags":16,"authorName":17,"seoTitle":18,"seoDescription":19},260,"potato-flakes-reducing-sugar-testing-guide","en","Reducing Sugar in Potato Flakes: Test Method, Reporting Basis and Frying-Color Interpretation","Reducing-sugar figures on potato flakes COAs are not always directly comparable. Learn how copper-reduction titration, DNS and HPLC differ, how to interpret dry-basis versus as-received results, and what these measurements can tell industrial buyers about frying colour.","\u003Cp>Two suppliers send certificates of analysis for potato flakes. Both documents show a reducing-sugar percentage. One laboratory used a heated copper-reduction titration and reported the result on an as-received basis. The other quantified glucose and fructose by chromatography and reported the result on a dry basis. The purchasing team notices that the numbers are close and asks which product will fry lighter.\u003C\u002Fp>\u003Cp>The answer is not available from those two percentages alone. Before comparing products, QA must determine \u003Cstrong>what was measured, how it was measured and what mass the percentage refers to\u003C\u002Fstrong>.\u003C\u002Fp>\u003Cp class=\"jua-answer\">\u003Cstrong>Direct answer:\u003C\u002Fstrong> Reducing sugar in potato flakes is a useful indicator for browning-sensitive food applications, especially fabricated potato chips, but laboratory results are comparable only when sample identity, extraction, analytical method, calibration, units and moisture basis are aligned. Copper-reduction titration, DNS colour measurement and HPLC do not necessarily report the same chemical quantity. Even correctly aligned results cannot by themselves guarantee frying colour: the complete formula and actual frying conditions must also be evaluated.\u003C\u002Fp>\u003Ch2 id=\"junsheng-pf-article-03-section-01\">1. What does “reducing sugar” mean in dehydrated potato flakes?\u003C\u002Fh2>\u003Cp>Potatoes contain starch and smaller amounts of soluble sugars. \u003Cstrong>Glucose and fructose\u003C\u002Fstrong> are the reducing sugars most frequently discussed in potato frying performance. They can participate in the Maillard reaction with amino compounds during heating, contributing to desirable flavour and colour at appropriate levels and excessive browning under other conditions.\u003C\u002Fp>\u003Cp>Sucrose is a major non-reducing sugar: it cannot simply be counted as glucose or fructose in a test that measures reducing sugars without a suitable conversion step. Some methods, however, can be affected by extraction or hydrolysis conditions that change the sugar mixture before measurement. That is one reason why the exact analytical procedure matters.\u003C\u002Fp>\u003Cp>The term \u003Cem>total reducing sugar\u003C\u002Fem> may mean different things on different reports: a value expressed as glucose equivalents by a copper-reduction method, an absorbance-based DNS result expressed against a glucose calibration, or the sum of individually quantified glucose and fructose concentrations. A report should state which definition it uses.\u003C\u002Fp>\u003Ch3 id=\"article-heading-1\">Why the fresh-potato result is not the same as the finished-flakes result\u003C\u002Fh3>\u003Cp>Fresh potatoes contain much more water than dehydrated flakes. Comparing 0.2% reducing sugar in a fresh tuber with 1.2% in a dried ingredient, for example, would be misleading without converting the mass basis and understanding the changes that may occur during processing. Peeling, blanching, cooking, drying and storage can also affect the final sugar profile. The raw-potato value is a process-control indicator; the finished-flake value is the more directly relevant supply specification for a buyer purchasing dehydrated flakes.\u003C\u002Fp>\u003Cp>A procurement document should therefore name the sample material explicitly: \u003Cem>fresh potato\u003C\u002Fem>, \u003Cem>potato flakes\u003C\u002Fem>, \u003Cem>potato granules\u003C\u002Fem> or \u003Cem>finished formulated dough\u003C\u002Fem>. These are not interchangeable analytical samples.\u003C\u002Fp>\u003Cimg src=\"https:\u002F\u002Fcms.potahub.com\u002Fassets\u002F748dbd6f-e205-4ac3-80b9-49d2e7ff0c70.png?width=1448&amp;height=1086\" alt=\"01\" loading=\"lazy\" \u002F>\u003Ch2 id=\"junsheng-pf-article-03-section-02\">2. Three approaches to measuring reducing sugars—and what each tells the buyer\u003C\u002Fh2>\u003Ch3 id=\"article-heading-2\">Heated copper-reduction titration, often described as a Fehling-type method\u003C\u002Fh3>\u003Cp>In copper-reduction methods, reducing substances react with an alkaline copper reagent under defined heating conditions. The endpoint is determined through a prescribed procedure, and the amount of sample needed to reach the endpoint is related to a calibrated reducing-sugar standard. The result is often expressed as glucose or another defined equivalent.\u003C\u002Fp>\u003Cp>China's \u003Cstrong>GB 5009.7-2016, National Food Safety Standard—Determination of Reducing Sugar in Foods\u003C\u002Fstrong>, includes a first method based on direct titration using alkaline copper tartrate under heating and a methylene-blue indicator. The standard specifies applicability for its different methods; the food matrix and method selected must be checked when ordering the analysis.\u003C\u002Fp>\u003Cp>Titration quantifies reducing capacity without identifying individual sugars. Sample preparation, non-sugar reducing substances, endpoint control and calibration can affect the result. The buyer must know the reporting equivalent.\u003C\u002Fp>\u003Ch3 id=\"article-heading-3\">DNS colour measurement\u003C\u002Fh3>\u003Cp>The 3,5-dinitrosalicylic acid (DNS) assay produces a coloured reaction with reducing substances under alkaline heated conditions. The intensity is measured by absorbance and compared with a calibration curve, frequently prepared using glucose. For screening work, this may be convenient when performed with appropriate controls.\u003C\u002Fp>\u003Cp>DNS is not inherently selective for only glucose and fructose. Other reactive compounds can alter colour development, and sample colour or background absorbance may interfere. Published analytical research has documented interference from certain amino acids and other compounds in DNS-based reducing-sugar measurement. These observations illustrate a method limitation; they do not establish that a particular potato-flakes sample necessarily contains those interferents at problematic levels.\u003C\u002Fp>\u003Cp>Where DNS is used for supplier comparison, the two laboratories should agree on the extraction, reagent conditions, wavelength, calibration material, blank subtraction and any dilution or matrix-effect control. A DNS glucose-equivalent result should not be silently presented as an HPLC sum of glucose and fructose.\u003C\u002Fp>\u003Ch3 id=\"article-heading-4\">HPLC or another validated chromatographic sugar-profile method\u003C\u002Fh3>\u003Cp>High-performance liquid chromatography can separate and quantify individual sugars when an appropriate column, mobile phase, detector, calibration and sample preparation are used. Depending on the method, the laboratory may report glucose and fructose separately and, if included, sucrose or other sugars. The sum of measured glucose and fructose is a chemically more specific result than a general reducing-capacity assay.\u003C\u002Fp>\u003Cp>Chromatography is not automatically correct under every condition. Poor separation, incomplete extraction, calibration errors, co-eluting substances and unsuitable detection settings can still produce misleading figures. The laboratory's method needs to be fit for the potato ingredient matrix and the concentration range of interest.\u003C\u002Fp>\u003Ch3 id=\"article-heading-5\">A comparison table for procurement and QA\u003C\u002Fh3>\u003Ctable>\u003Ccolgroup>\u003Ccol \u002F>\u003Ccol \u002F>\u003Ccol \u002F>\u003Ccol \u002F>\u003Ccol \u002F>\u003C\u002Fcolgroup>\u003Ctbody>\u003Ctr>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Test approach\u003C\u002Fp>\u003C\u002Fth>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Main analytical signal\u003C\u002Fp>\u003C\u002Fth>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Typical report expression\u003C\u002Fp>\u003C\u002Fth>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Practical strength\u003C\u002Fp>\u003C\u002Fth>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Main interpretation issue\u003C\u002Fp>\u003C\u002Fth>\u003C\u002Ftr>\u003Ctr>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Direct heated copper-reduction titration\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Copper reduction under defined conditions\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Reducing sugar as a specified standard equivalent\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Established standardized approach for relevant food testing\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Measures overall reducing response, not individual sugar identities\u003C\u002Fp>\u003C\u002Ftd>\u003C\u002Ftr>\u003Ctr>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>DNS colour assay\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Colour\u002Fabsorbance response to reducing substances\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Often glucose equivalents\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Useful for validated screening and comparative studies\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Matrix and reagent interferences; method conditions matter\u003C\u002Fp>\u003C\u002Ftd>\u003C\u002Ftr>\u003Ctr>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>HPLC sugar analysis\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Separation and measurement of sugar components\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Glucose and fructose individually, sometimes their mass sum\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Sugar-specific profile when validated\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Requires proper separation, standards and quantitative recovery\u003C\u002Fp>\u003C\u002Ftd>\u003C\u002Ftr>\u003C\u002Ftbody>\u003C\u002Ftable>\u003Cp>All three may be technically useful in their appropriate context. The best method for a purchasing contract is the one that both parties can specify, execute consistently, audit and interpret against the agreed acceptance criteria.\u003C\u002Fp>\u003Ch2 id=\"junsheng-pf-article-03-section-03\">3. Reporting basis: as received, dry basis and concentration units\u003C\u002Fh2>\u003Cp>A sugar percentage is only unambiguous when its denominator is defined.\u003C\u002Fp>\u003Cp>\u003Cstrong>As-received basis (wet basis)\u003C\u002Fstrong> reports grams of analyte per 100 grams of the material in the condition in which it was tested, including its moisture.\u003C\u002Fp>\u003Cp>\u003Cstrong>Dry basis\u003C\u002Fstrong> reports grams of analyte relative to the sample's dry matter. It adjusts for water and can help compare samples with different moisture, provided the moisture and sugar measurements are valid and correspond to the same specimen.\u003C\u002Fp>\u003Cp>For a sample with moisture \u003Cstrong>M%\u003C\u002Fstrong>:\u003C\u002Fp>\u003Cp>\u003Cstrong>Reducing sugar, dry basis (%) = Reducing sugar, as-received basis (%) × 100 ÷ (100 − M).\u003C\u002Fstrong>\u003C\u002Fp>\u003Cp>The reverse is:\u003C\u002Fp>\u003Cp>\u003Cstrong>Reducing sugar, as-received basis (%) = Reducing sugar, dry basis (%) × (100 − M) ÷ 100.\u003C\u002Fstrong>\u003C\u002Fp>\u003Cp>For example, a hypothetical potato-flakes sample has \u003Cstrong>7.0% moisture\u003C\u002Fstrong> and an analytically determined reducing-sugar value of \u003Cstrong>1.40% on a dry basis\u003C\u002Fstrong>. Its corresponding as-received value is \u003Cstrong>1.40 × 0.93 = 1.302%\u003C\u002Fstrong>, commonly rounded to \u003Cstrong>1.30%\u003C\u002Fstrong>. These two figures refer to the \u003Cem>same amount of sugar in the same sample\u003C\u002Fem>, not an improvement in product quality.\u003C\u002Fp>\u003Cp>The conversion corrects only for moisture. It does \u003Cstrong>not\u003C\u002Fstrong> resolve differences between a titration result expressed as glucose equivalents and an HPLC result expressed as glucose-plus-fructose mass.\u003C\u002Fp>\u003Ch3 id=\"article-heading-6\">Understanding mg\u002Fg, g\u002F100 g and percentages\u003C\u002Fh3>\u003Cp>When the same analyte and basis are used:\u003C\u002Fp>\u003Cul>\u003Cli>\u003Cp>\u003Cstrong>1 g per 100 g = 1.0%\u003C\u002Fstrong> by mass.\u003C\u002Fp>\u003C\u002Fli>\u003Cli>\u003Cp>\u003Cstrong>10 mg per g = 1.0%\u003C\u002Fstrong> by mass.\u003C\u002Fp>\u003C\u002Fli>\u003Cli>\u003Cp>\u003Cstrong>1,000 mg per kg = 0.10%\u003C\u002Fstrong> by mass.\u003C\u002Fp>\u003C\u002Fli>\u003C\u002Ful>\u003Cp>A report using mg\u002Fkg may look numerically large compared with a percentage, even though the concentration is the same. QA should convert units before discussing pass\u002Ffail. The reporting limit and rounding rule also matter near a contract boundary.\u003C\u002Fp>\u003Ch2 id=\"junsheng-pf-article-03-section-04\">4. What a comparable reducing-sugar report must show\u003C\u002Fh2>\u003Cp>For supplier approval, a useful report identifies the product and gives enough method information for another qualified laboratory to reproduce the result. The buyer should ask for these fields, especially when comparing two new suppliers.\u003C\u002Fp>\u003Ctable>\u003Ccolgroup>\u003Ccol \u002F>\u003Ccol \u002F>\u003C\u002Fcolgroup>\u003Ctbody>\u003Ctr>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Report field\u003C\u002Fp>\u003C\u002Fth>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Why it matters\u003C\u002Fp>\u003C\u002Fth>\u003C\u002Ftr>\u003Ctr>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Product and grade\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Prevents comparisons between flakes, granules or different controlled grades\u003C\u002Fp>\u003C\u002Ftd>\u003C\u002Ftr>\u003Ctr>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Sample\u002Flot identification\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Connects the analysis to the material actually offered\u003C\u002Fp>\u003C\u002Ftd>\u003C\u002Ftr>\u003Ctr>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Sample date and condition\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Helps interpret handling and storage history\u003C\u002Fp>\u003C\u002Ftd>\u003C\u002Ftr>\u003Ctr>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Method name and standard\u002Fversion\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Establishes the tested chemical response and analytical procedure\u003C\u002Fp>\u003C\u002Ftd>\u003C\u002Ftr>\u003Ctr>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Extraction and sample preparation\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Can determine which sugars are recovered or altered\u003C\u002Fp>\u003C\u002Ftd>\u003C\u002Ftr>\u003Ctr>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Analytes or equivalent basis\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Distinguishes glucose-plus-fructose from glucose-equivalent totals\u003C\u002Fp>\u003C\u002Ftd>\u003C\u002Ftr>\u003Ctr>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Unit and wet\u002Fdry basis\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Makes the denominator and concentration clear\u003C\u002Fp>\u003C\u002Ftd>\u003C\u002Ftr>\u003Ctr>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Moisture value, if converted\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Allows the reported dry-basis calculation to be checked\u003C\u002Fp>\u003C\u002Ftd>\u003C\u002Ftr>\u003Ctr>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Quantification limit, uncertainty or repeatability as relevant\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Helps assess borderline results and test reliability\u003C\u002Fp>\u003C\u002Ftd>\u003C\u002Ftr>\u003Ctr>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Laboratory and report identification\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Supports traceability and document review\u003C\u002Fp>\u003C\u002Ftd>\u003C\u002Ftr>\u003C\u002Ftbody>\u003C\u002Ftable>\u003Cp>For food-manufacturing acceptance, contract wording should also identify the frequency of lot testing, release rule and how any disputed result will be resolved. A number without an agreed test method is a weak contractual requirement.\u003C\u002Fp>\u003Ch2 id=\"junsheng-pf-article-03-section-05\">5. Sampling can change the answer before the chemistry begins\u003C\u002Fh2>\u003Cp>Even an excellent laboratory method can give a misleading result if the submitted material does not represent the lot. Poor subsampling may overrepresent fine or large pieces; supplier and customer samples may differ because of handling rather than a true lot change.\u003C\u002Fp>\u003Cp>A controlled procedure should identify the number and location of bags sampled, whether the samples are composite or individually tested, how the material is homogenized without introducing avoidable heat or moisture and how the final laboratory portion is selected. The protocol should be recorded before samples are drawn, not reconstructed after a disagreement appears.\u003C\u002Fp>\u003Cp>Sample preparation must also protect the analyte. Strong conditions that hydrolyze sucrose or alter sugars can change what is ultimately measured. Extraction volume, time, temperature, clarification and filtration should follow the validated method. For chromatographic methods, the analyst should examine extraction recovery and whether the detector can separate the components of interest.\u003C\u002Fp>\u003Ch3 id=\"article-heading-7\">Essential quality-control checks\u003C\u002Fh3>\u003Cp>A defensible analytical programme normally considers suitable calibration standards, method blanks, appropriate duplicates, control samples or recovery checks and documented instrument or titration performance. The necessary controls depend on the selected method. If a result falls very close to an acceptance limit, the agreed rule should explain whether to repeat the same method, re-sample or refer the dispute to a qualified independent laboratory.\u003C\u002Fp>\u003Cp>A laboratory should not simply average two results from different methods and call the mean a more accurate reducing-sugar value. Different methods can respond to different chemical species.\u003C\u002Fp>\u003Ch2 id=\"junsheng-pf-article-03-section-06\">6. A worked buyer comparison: two certificates that seem equivalent\u003C\u002Fh2>\u003Cp>Imagine two prospective lots reported as follows. These are \u003Cstrong>calculation examples\u003C\u002Fstrong>, not actual Junsheng lot data.\u003C\u002Fp>\u003Ctable>\u003Ccolgroup>\u003Ccol \u002F>\u003Ccol \u002F>\u003Ccol \u002F>\u003C\u002Fcolgroup>\u003Ctbody>\u003Ctr>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Field\u003C\u002Fp>\u003C\u002Fth>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Supplier A\u003C\u002Fp>\u003C\u002Fth>\u003Cth colspan=\"1\" rowspan=\"1\">\u003Cp>Supplier B\u003C\u002Fp>\u003C\u002Fth>\u003C\u002Ftr>\u003Ctr>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Product\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Potato flakes\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Potato flakes\u003C\u002Fp>\u003C\u002Ftd>\u003C\u002Ftr>\u003Ctr>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Result\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>1.30%\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>1.40%\u003C\u002Fp>\u003C\u002Ftd>\u003C\u002Ftr>\u003Ctr>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Reporting basis\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>As received\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Dry basis\u003C\u002Fp>\u003C\u002Ftd>\u003C\u002Ftr>\u003Ctr>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Moisture\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>7.0%\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>7.0%\u003C\u002Fp>\u003C\u002Ftd>\u003C\u002Ftr>\u003Ctr>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Analysis\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Copper-reduction titration, glucose equivalents\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>HPLC, glucose + fructose sum\u003C\u002Fp>\u003C\u002Ftd>\u003C\u002Ftr>\u003Ctr>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>Moisture-adjusted percentage\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>About 1.40% dry basis\u003C\u002Fp>\u003C\u002Ftd>\u003Ctd colspan=\"1\" rowspan=\"1\">\u003Cp>1.40% dry basis\u003C\u002Fp>\u003C\u002Ftd>\u003C\u002Ftr>\u003C\u002Ftbody>\u003C\u002Ftable>\u003Cp>After the moisture conversion, the numbers look almost identical. \u003Cstrong>That still does not make the lots analytically equivalent\u003C\u002Fstrong>: one value reflects a defined reducing-capacity response and the other represents chromatographically quantified sugars. Before writing “both pass the same 1.40% requirement,” the customer must verify whether the purchasing specification permits both methods or requires one agreed method.\u003C\u002Fp>\u003Cp>For a sound comparison, the buyer can request repeat analysis under a single validated method and reporting basis, ideally with controlled sampling. If several laboratories are involved, the reference method and dispute process should be decided in advance. This is much more useful than asking the suppliers to issue certificates with matching decimal places.\u003C\u002Fp>\u003Cimg src=\"https:\u002F\u002Fcms.potahub.com\u002Fassets\u002F1c3213e2-f30b-4883-a10a-2864c403d8d3.png?width=1600&amp;height=1200\" alt=\"002\" loading=\"lazy\" \u002F>\u003Ch2 id=\"junsheng-pf-article-03-section-07\">7. From reducing sugar to frying colour: an important but incomplete link\u003C\u002Fh2>\u003Cp>The Maillard reaction is a principal source of colour in fried potato products. It involves reducing sugars and amino compounds, and its progression depends on temperature, time, moisture and food composition. Glucose and fructose can behave differently in browning and acrylamide formation; the total number does not fully describe those differences.\u003C\u002Fp>\u003Cp>For fabricated chips, the finished colour is also affected by the other dry ingredients, their reducing-sugar contribution, amino acid availability, dough pH, hydration, sheet thickness, oil temperature, frying time and final moisture. A batch of flakes that meets the agreed reducing-sugar target can still produce a darker chip if the formula or fryer programme differs from the approved trial.\u003C\u002Fp>\u003Cp>A meaningful factory trial therefore holds the important processing variables constant and records final colour, preferably under a documented light source or instrument procedure. A CIELAB measurement may help when consistently performed, but a visual acceptance panel or calibrated factory colour standard may also be appropriate to the product. The buyer and supplier should agree which finished-product measure determines acceptance.\u003C\u002Fp>\u003Ch3 id=\"article-heading-8\">Reducing sugar and acrylamide are related, not interchangeable measurements\u003C\u002Fh3>\u003Cp>Reducing sugars and asparagine contribute to acrylamide formation in certain high-temperature foods, but reducing sugar concentration is not itself a direct measurement of finished-product acrylamide. Neither a pale chip nor an acceptable ingredient COA establishes final-product acrylamide compliance. Manufacturing conditions and product-specific mitigation controls must be considered.\u003C\u002Fp>\u003Cp>For EU dough-based potato crisps and snacks, \u003Cstrong>Commission Regulation (EU) 2017\u002F2158\u003C\u002Fstrong> includes a requirement to set reducing-sugar target values in dehydrated potato ingredients as low as feasibly possible, taking account of the formulation and process. It also addresses cases in which reducing-sugar content exceeds \u003Cstrong>1.5%\u003C\u002Fstrong>, requiring supporting data demonstrating appropriate acrylamide reduction in the finished product. This is a specific regulatory risk-management provision, \u003Cstrong>not\u003C\u002Fstrong> a global declaration that every value up to 1.5% guarantees safety, good colour or compliance. Customers elsewhere should apply the relevant local legal and product specifications.\u003C\u002Fp>\u003Cp>Some manufacturers adopt a stricter internal procurement target such as \u003Cstrong>1.2%\u003C\u002Fstrong> where their application warrants it. The contract should still identify method and basis. Different targets cannot be meaningfully enforced if the laboratory is free to change how the percentage is generated.\u003C\u002Fp>\u003Ch2 id=\"junsheng-pf-article-03-section-08\">8. A quality-approval workflow for ingredient buyers\u003C\u002Fh2>\u003Cp>\u003Cstrong>1. Identify the product and application.\u003C\u002Fstrong> Specify potato flakes, the exact proposed grade and the finished-food process. Decide whether reducing sugar is a critical release parameter for that application.\u003C\u002Fp>\u003Cp>\u003Cstrong>2. Write the number with a method and basis.\u003C\u002Fstrong> Use a complete expression such as “reducing sugar as defined by the agreed method, reported on a dry-product basis,” followed by the actual contractual limit. If a specific glucose\u002Ffructose determination is required, name both analytes and the validated method.\u003C\u002Fp>\u003Cp>\u003Cstrong>3. Obtain an identifiable sample and report.\u003C\u002Fstrong> Match the sample reference to the supplier's TDS and lot-related COA. Confirm that the laboratory report actually covers the stated sample.\u003C\u002Fp>\u003Cp>\u003Cstrong>4. Compare the candidate with an approved control.\u003C\u002Fstrong> Where possible, use one laboratory method for both. Record moisture, sampling procedure and the result's analyte basis.\u003C\u002Fp>\u003Cp>\u003Cstrong>5. Run a controlled application trial.\u003C\u002Fstrong> For fabricated chips, fix formula, water, dough mixing, sheet thickness, frying conditions and test endpoint. Measure finished colour and assess texture, moisture and product acceptance.\u003C\u002Fp>\u003Cp>\u003Cstrong>6. Approve the grade and document changes.\u003C\u002Fstrong> Keep the accepted reference sample, numerical specification and trial notes connected to the relevant product code. If the supplier changes grade, process or declared characteristics, reassess the applicable controls.\u003C\u002Fp>\u003Cp>\u003Cstrong>7. Set the shipment verification plan.\u003C\u002Fstrong> Agree which parameters will be checked for each production lot or shipment, what evidence accompanies the order and how a disagreement is investigated.\u003C\u002Fp>\u003Ch2 id=\"junsheng-pf-article-03-section-09\">9. Junsheng Agriculture's approach to reducing-sugar discussions\u003C\u002Fh2>\u003Cp>At \u003Cstrong>Hebei Junsheng Agricultural Technology Co., Ltd.\u003C\u002Fstrong> in Shangyi County, Hebei Province, potato flakes and potato granules are treated as distinct industrial ingredients with different physical behaviour and application requirements. The company accepts fresh potatoes against a dry-matter requirement \u003Cstrong>strictly above 19% on a fresh-weight basis\u003C\u002Fstrong>, alongside its other raw-material controls. Dry matter and reducing sugar are different parameters; meeting one requirement does not establish the result of the other.\u003C\u002Fp>\u003Cp>For fried-snack customers, Junsheng can discuss a \u003Cstrong>low-reducing-sugar grade\u003C\u002Fstrong> as well as standard or other grade options according to the intended product. Buyers should align reducing sugar, visible specks and other contractual criteria with the selected grade instead of assuming that one test result covers every product. Current product information and batch testing documentation can be reviewed for the specified material.\u003C\u002Fp>\u003Cp>A recent measured bulk-density reference for Junsheng potato flakes is \u003Cstrong>360 g\u002FL\u003C\u002Fstrong>; this physical measurement is separate from reducing sugar and depends on the test conditions. The company's core declared formulation is \u003Cstrong>99.5% potato plus 0.5% monoglyceride\u003C\u002Fstrong>, and standard packing is \u003Cstrong>25 kg per bag\u003C\u002Fstrong>. Packaging, product documentation and destination-market requirements can be discussed for the relevant order.\u003C\u002Fp>\u003Cp>Customers evaluating a China potato flakes manufacturer can share their target reducing-sugar limit, approved test method, dry- or as-received basis, intended recipe and finished frying-colour requirement. That information allows a far more precise sample discussion than the request “Send your lowest-sugar powder.”\u003C\u002Fp>\u003Cimg src=\"https:\u002F\u002Fcms.potahub.com\u002Fassets\u002F588ebeab-463d-4de3-8c6b-e7753c46a07e.png?width=1448&amp;height=1086\" alt=\"02\" loading=\"lazy\" \u002F>\u003Ch2 id=\"junsheng-pf-article-03-section-10\">10. Frequently asked questions about potato-flakes reducing sugar\u003C\u002Fh2>\u003Ch3 id=\"article-heading-9\">Which reducing sugars are most relevant in potato flakes?\u003C\u002Fh3>\u003Cp>Glucose and fructose are usually central to discussion of potato frying behaviour. A laboratory may report them separately or provide a total reducing-capacity result depending on the selected method. Buyers should ask which chemical quantity the specification actually controls.\u003C\u002Fp>\u003Ch3 id=\"article-heading-10\">Why is the analytical method important?\u003C\u002Fh3>\u003Cp>Different methods can respond to different substances. Titration and DNS generally measure reducing responses under defined conditions, while an appropriate HPLC procedure can distinguish particular sugars. Using different methods without cross-validation can create misleading comparisons even if the printed units are identical.\u003C\u002Fp>\u003Ch3 id=\"article-heading-11\">Can Fehling-type titration and HPLC results be compared directly?\u003C\u002Fh3>\u003Cp>Not automatically. A titration result expressed as glucose equivalents and an HPLC result summing glucose and fructose are not necessarily identical. Agree on the reference method, sample preparation and basis, or conduct a documented comparison study before transferring an acceptance limit from one method to the other.\u003C\u002Fp>\u003Ch3 id=\"article-heading-12\">What does “reducing sugar on a dry basis” mean?\u003C\u002Fh3>\u003Cp>It expresses the amount of the measured reducing-sugar quantity relative to the dry matter in the sample rather than the original total sample mass. The conversion requires the moisture percentage of the same sample. It does not change which sugars the analytical method measures.\u003C\u002Fp>\u003Ch3 id=\"article-heading-13\">How does product moisture affect the percentage?\u003C\u002Fh3>\u003Cp>On an as-received basis, additional moisture increases the denominator and can make an unchanged sugar mass appear as a lower percentage. A correct dry-basis conversion removes that dilution effect. Moisture should be measured appropriately and reported with the sugar result whenever conversion is needed.\u003C\u002Fp>\u003Ch3 id=\"article-heading-14\">Does a low reducing-sugar result guarantee a light frying colour?\u003C\u002Fh3>\u003Cp>No. It reduces one important source of browning potential but does not control the complete recipe, amino compounds, dough pH or frying conditions. Verify the selected flakes in a controlled finished-product test using the customer's colour acceptance standard.\u003C\u002Fp>\u003Ch3 id=\"article-heading-15\">Why might two laboratories obtain different results?\u003C\u002Fh3>\u003Cp>Sampling, extraction, calibration, analytical method, endpoint reading, dilution, reporting basis and measurement uncertainty can all differ. Start by checking whether the same lot was sampled representatively and whether the laboratories reported the same analyte definition and basis.\u003C\u002Fp>\u003Ch3 id=\"article-heading-16\">How should purchasing teams read reducing sugar on a COA?\u003C\u002Fh3>\u003Cp>Look beyond the number. Confirm product grade, lot, method, analyte or equivalent, unit, wet\u002Fdry basis, moisture when applicable and the contract limit. A batch certificate can support a purchasing decision only when it matches the agreed specification and material identity.\u003C\u002Fp>\u003Ch3 id=\"article-heading-17\">What belongs in a reducing-sugar purchase specification?\u003C\u002Fh3>\u003Cp>State the exact product and grade, selected test method or agreed equivalent, result expression, unit, wet- or dry-basis rule, numerical limit, sampling and frequency requirements and procedure for disputed values. Where frying performance is critical, add a separate, documented application-approval criterion.\u003C\u002Fp>\u003Ch3 id=\"article-heading-18\">How frequently should reducing sugar be checked?\u003C\u002Fh3>\u003Cp>The appropriate schedule depends on the product, manufacturing risk, supplier history, contract and process controls. A buyer may require lot-specific verification for a critical fried-snack ingredient. Frequency should be agreed explicitly; it should not be inferred from a single sample report.\u003C\u002Fp>\u003Ch3 id=\"article-heading-19\">Can raw-potato storage affect later reducing-sugar levels?\u003C\u002Fh3>\u003Cp>Yes. Potato variety, physiological condition and storage temperature can influence sugar accumulation in raw tubers. In particular, some potatoes accumulate reducing sugars when kept too cold. The exact response varies, and finished dehydrated ingredients must still be measured on their own defined analytical basis.\u003C\u002Fp>\u003Ch3 id=\"article-heading-20\">Which method should buyers select when comparing new suppliers?\u003C\u002Fh3>\u003Cp>Choose a validated method suitable for the food matrix and the contractual objective, and apply it consistently. A standardized titration may fit a defined total reducing-sugar requirement; chromatography may be more informative when individual glucose and fructose values are important. Consistency, traceability and interpretability matter more than method prestige.\u003C\u002Fp>\u003Ch2 id=\"junsheng-pf-article-03-section-11\">11. Match analytical numbers to real manufacturing decisions\u003C\u002Fh2>\u003Cp>A responsible reducing-sugar specification is more than a percentage. It links a defined laboratory procedure to an identified lot and then tests whether that result predicts acceptable performance in the real food. When those steps are aligned, procurement can compare suppliers more fairly, QA can investigate borderline results more efficiently and R&amp;D can distinguish ingredient effects from process effects.\u003C\u002Fp>\u003Cp>Explore Junsheng's \u003Ca href=\"https:\u002F\u002Fchinapotatoflour.com\u002Fpotato-flakes\u002F\">Potato Flakes\u003C\u002Fa> and \u003Ca href=\"https:\u002F\u002Fchinapotatoflour.com\u002Fpotato-flour-quality-testing-methods\u002F\">Quality Testing for Buyer Approval\u003C\u002Fa>. Share your reducing-sugar method and reporting basis along with your application requirements when requesting a grade-specific sample.\u003C\u002Fp>\u003Csection class=\"jua-references\">\u003Ch3 id=\"article-heading-21\">Technical references\u003C\u002Fh3>\u003Cul>\u003Cli>\u003Cp>\u003Ca href=\"https:\u002F\u002Fwww.cfsn.cn\u002Fzcwk\u002Fdetail\u002F2163\u002F7747.html\">GB 5009.7-2016 — National Food Safety Standard: Determination of Reducing Sugar in Foods (Chinese Food Safety Network)\u003C\u002Fa>\u003C\u002Fp>\u003C\u002Fli>\u003Cli>\u003Cp>\u003Ca href=\"https:\u002F\u002Feur-lex.europa.eu\u002Feli\u002Freg\u002F2017\u002F2158\">Commission Regulation (EU) 2017\u002F2158 — Acrylamide mitigation measures\u003C\u002Fa>\u003C\u002Fp>\u003C\u002Fli>\u003Cli>\u003Cp>\u003Ca href=\"https:\u002F\u002Fpubmed.ncbi.nlm.nih.gov\u002F32289426\u002F\">Deshavath et al. (2020), Pitfalls in the DNS assay for reducing sugars: interference from furfural and 5-HMF\u003C\u002Fa>\u003C\u002Fp>\u003C\u002Fli>\u003Cli>\u003Cp>\u003Ca href=\"https:\u002F\u002Fpubmed.ncbi.nlm.nih.gov\u002F23103512\u002F\">Teixeira et al. (2012), Amino acid interference in DNS measurement\u003C\u002Fa>\u003C\u002Fp>\u003C\u002Fli>\u003Cli>\u003Cp>\u003Ca href=\"https:\u002F\u002Fpubmed.ncbi.nlm.nih.gov\u002F25540460\u002F\">Evidence for the relationship between free amino acids, sugars and acrylamide-forming potential in potato\u003C\u002Fa>\u003C\u002Fp>\u003C\u002Fli>\u003C\u002Ful>\u003C\u002Fsection>\u003Csection class=\"jua-contact\">\u003Cp>\u003Cstrong>Hebei Junsheng Agricultural Technology Co., Ltd.\u003C\u002Fstrong>\u003Cbr \u002F>Email: \u003Ca href=\"mailto:potato@chineseag.com\">potato@chineseag.com\u003C\u002Fa>\u003Cbr \u002F>Phone: +86 400-613-9889\u003Cbr \u002F>WhatsApp: +86 150 8136 8488\u003Cbr \u002F>Website: \u003Ca href=\"http:\u002F\u002Fchinapotatoflour.com\">chinapotatoflour.com\u003C\u002Fa>\u003Cbr \u002F>Contact: \u003Ca href=\"https:\u002F\u002Fchinapotatoflour.com\u002Fcontact\u002F\">Discuss your reducing-sugar specification\u003C\u002Fa>\u003C\u002Fp>\u003C\u002Fsection>\u003Cp>\u003C\u002Fp>","2026-11-01T18:27:00","\u002Ftechnical-blog\u002Fpotato-flakes-reducing-sugar-testing-guide\u002F","https:\u002F\u002Fcms.potahub.com\u002Fassets\u002F607ae21b-6361-4be2-ab3b-e7d49f93ca71",[],[],"Junsheng","Reducing Sugar in Potato Flakes: Tests & COA Guide","Compare titration, DNS and HPLC results for potato flakes. Understand dry versus as-received reporting, COA comparisons and frying-colour interpretation.",{"previous":21,"next":24},{"slug":22,"title":23},"potato-flakes-grade-selection-guide","Low-Sugar, Standard and Higher-Speck Potato Flakes: A Practical Grade Selection Guide",{"slug":25,"title":26},"fabricated-potato-chips-dark-frying-troubleshooting","Why Fabricated Potato Chips Fry Too Dark Even When Reducing Sugar Meets Specification",1795351320719]